Replace Slide Piece, Honda Activa 125, SCV125
Disassemble
It’s easier to remove the Slide Pieces from Ramp Plate using your fingers strength
Dr.Pulley Material
High Performance Material
Dr.Pulley SP-AS that replace OEM parts number 22011-K24-900 have better duability, There are a little benefits below:
- Low Friction
- Non Abrasive
- Strong Wear Resistance
- Aluminium Friendly
Assemble
There are a bit of gists for assemble:
- Simple way is the Curve against the curve,
- Further pushing with your thumb finger, or as one example, pressing the Ramp Plate with the hard flat something like iron block, and then could slightly sway it under pressing.
Check
You should inspect their movement whether still excessive resistance as up and down before you ready go to put on Variator Set to the vehicle. Simulating Scooter’s acutally situation, having to assemble relative parts are Variator Boss and Weight Rollers, put it on with the Variator (Moveable drive variator), we recommend the way to do, and then check the Slide Piece movement by try to move or push up the Variator Boss from its bottom.
Notice
if you have our Dr.Pulley’s products from Sliding Roller Weight, be watch out when checking process, when you check it by moving the Ramp Plate as up and down, the Sliding Roller Weight easy flip out or not back to initial position of lowest point, therefore, making sure correct the setting, and tightly cramp the Ramp Plate and the Variator in order to avoid the Sliding Roller Weight wrong position at the moment until fix to on the Engine drive axis.
Video
More Information
Our Youtube url : https://www.youtube.com/c/DrPulley